ThermoFloor Warming Pad Specifications
Materials: Blended synthetic fibers
Weight: 25oz/sqyd (2.78 oz/sqft)
Thickness: 0.11"
Density: 18.9 lbs/ft^3
R-Value: 0.5 [@0.11" = 0.46 hr-ft^2-degF/Btu (4.19/inch)]
Flammability: Meets or exceeds Federal Flammability Standard: CPSC FF 1-70 (Pill Test)
Sound - Field Impact Insulation Class (FIIC)
3/8 Engineered wood flooring over Insulayment, over 8 concrete sub-floor with no ceiling assembly (double glued). FIIC = 60.
Ceramic tile over Insulayment (latex modified thin set and grout), over 8 concrete sub-floor with no ceiling assembly. FIIC = 60.
Sound - Impact Insulation Class (IIC)
Ceramic tile over Insulayment (latex modified thin set and grout), over wood floor structure with 1 1/2 of Gypcrete. IIC=52.
Sound Transmission Class (STC)
Ceramic tile over Insulayment (latex modified thin set and grout), over wood floor structure with 1 1/2 of Gypcrete. STC=53.
Physical Properties:
Compression Resistance @ 25%23.2psi
Compression Resistance @ 30%37.0psi
Compression Resistance @ 50%219.6psi
Compression Set @ 25%18.8%
Tensile StrengthLength 78.4lbs, Width 63.3lbs
Weight and Density +/- 10% tolerance. Thickness +/- 5% tolerance.
Performance Level:
Rated as "Extra Heavy" for "extra heavy and high impact use in food plants, dairies, breweries, and kitchens" when installed using porcelain tile & epoxy grout. (ASTM C627 Robinson Floor Test)
Rated as "Light Commercial" for "office space, reception areas, kitchens, and bathrooms" when installed using residential tile and latex modified thin set and grout. (ASTM C627 Robinson Floor Test)
|