Tag Archives: Pipe tracing

Pipe Trace Systems

Solutions for Industrial, Commercial and Residential Applications

As a leading provider of radiant heat solutions, Warmzone has earned its reputation as a trusted industry leader. Having designed systems that have been installed in large refineries, commercial facilities and custom residential applications, Warmzone’s expertise is a valuable asset to businesses or homeowners seeking a reliable pipe trace solution.

Heat cable on pipes for pipe tracing system

Warmzone pipe trace systems can be installed for pipe freeze prevention as well as process temperature maintenance installations. The self-regulating heat cable is UL listed and approved for hazardous and non-hazardous applications. It can be used for plastic or metal pipe freeze protection and flow maintenance of pipes, tanks, valves.

The self-regulating characteristics of the heat cable means that it automatically varies its power output in response to pipe temperature changes. When the ambient temperature rises, the electrical resistance increases and the consumption of electricity decreases. This ensures energy-efficient operation. The cable will also not overheat or burnout – even when touching or overlapping.

Additionally, because of the self-regulating properties, a thermostat may not be necessary in some applications. With the optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and protected against abrasion and impact damage. RHSR is suitable for use in explosion-hazardous areas up to a maximally admissible work-place temperature of +149° F (65° C).

Features Include:

Energy Efficient Operation – The self-regulating cable automatically varies its power output in response to pipe temperature changes. When the ambient temperature rises, the electrical resistance increases and the consumption of electricity decreases, ensuring energy-efficient operation. And the cable will not overheat or burnout – even when touching or overlapping.

Lower Cost – Less installation cost than steam tracing; less maintenance expense and less downtime.

Pipe trace heating cable installed

Safe / Durable – Does not overheat or burn out, even when touching or overlapping.

Versatile – Suitable for use in non-hazardous, hazardous and corrosive environments.

Easy Installation – The cable can be cut to any length required on site (up to max circuit length) so there’s no wasted cable. And the termination, power connection, splice, tee, and end seal kit reduces installation time and requires no special skills or tools.

Heat Cable Options Include:

Tinned copper braid provides additional mechanical protection and a positive ground path

Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions. It also protects against abrasion and impact damage.

The high-temperature Fluoropolymer outer jacket is used when there may be exposure to organic or corrosive solutions, or vapors may be present.

RHSR is UL listed, self-regulating parallel heating cable designed for a variety of industrial applications and environments, including hazardous and nonhazardous. It can be used for plastic or metal pipe freeze protection and flow maintenance of pipes, tanks, valves.

For more information about Warmzone’s products and services, call888.488.9276. 

Warmzone Roof Deicing Panels

Prevent Ice Dams from Forming

As we look forward to a warm summer, many residents in the north east are still reeling from the costly effects of record snowfall. Ice dams continue to be winter’s biggest culprit when it comes to roof damage.

Warm air slowly escapes from the home and into the attic where it warms the roof, causing snow to melt. As the runoff trickles down the roof, it reaches the eaves. Because the eaves extend out over the edges of the house, there is no warm air from the attic below. In the evening, the runoff will reach the cold eaves and refreeze. There, the ice continues to build up as more snow melts. The wall of ice causes water to build up behind it, refreezing every time the temperature dips below 32°Fahrenheit.

When the water pools up behind these ice dams, it can seep into tiny cracks in the roofing material where it refreezes and expands. This repeated process can eventually compromise the structure. Water can slowly work its way into the attic and then drip through the ceiling or down walls. Oftentimes the homeowner is not aware of any problem until significant water damage has occurred.

Warmzone offers an ideal way to protect homes and businesses from water damage. RoofHeat panels feature attractive aluminum panels with self-regulating heat cable. The panels are installed long the roof edge between the waterproof membrane and the shingle. The roof heating panels are supplied in 4-foot lengths and can be cut to length on site. Self-regulating heat cable is channeled through the panel, creating an effective roof deicing system that efficiently warms the roof edges help prevent ice dams from forming. The aluminum panels can also be installed in roof valleys to facilitate runoff.

Roof heating panel and heat cable

Features of the RoofHeat Panels Include:

  • Panels are made of aluminum
  • Deicing cables are inserted into the cable channel
  • Systems feature self-regulating heat cable
  • Shingles are installed on top of the panel, only the cable channel is visible
  • Panels can be painted to match the shingle color
  • Panels are 4-feet long and 6-inches wide with a cable channel
  • Panels that feature a slanted cable channel mount along the roof edge
  • Panels that feature a flat cable channel mount above the roof edge and along the inside
    of the valleys

Contact a Warmzone representative at 888.488.9276 for more information on our industry leading roof deicing solutions. There are many options available, and Warmzone will design a roof heating system that is unique to your specific roof heating needs. Call for more information or send us your project details for a free quote.

Unique Plumbing Challenges Can be Addressed with Pipe Tracing

Stop Pipes from Bursting

Living or working in a cold climate means you have to address certain challenges each winter. Snow removal, heating the interior, and keeping your pipes safe are just a few of the many quirks that come with enduring the winter. Homeowners and business owners alike have to face these challenges. Keeping your family and employees safe is the top priority, followed closely by keeping your property safe and running efficiently. Water pipes are a delicate part of your plumbing that must be monitored diligently and protected from freezing. Pipe tracing is an important part of the solution to that problem.

Heat trace cable installed on pipe of industrial facility.

Warehouses, attics, crawl spaces, or bonus rooms all have one thing in common; they are hard to heat and insulate properly. Insulation is always one of the top things on the check-list of things to do for these areas; and the pipes that weave in and out of these spaces should be added in the spot just below that in order to ensure they don’t burst during the coldest days and nights of winter. An unexpected cold snap could be the difference between a happy home or business and a miserable one. Bursting pipes resulting from frozen water can be potentially messy and very expensive to repair. Water damage is always a loaded problem, but pipe tracing can aid in the process of keeping your pipes safe. The heat cables wrap around your pipes and keep them consistently warm throughout the winter and are worth looking into if you have exposed pipes at home or in your work space. Contact Warmzone to request a quote to protect your pipes today!